Kern-sohn SMT 10K-3 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Balanças Kern-sohn SMT 10K-3. KERN & SOHN SMT 10K-3 User Manual [it] [es] [en] [de] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 37
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
email: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating instructions
Bottleweighing Balance
KERN SMT
Version 1.4
12/2014
GB
SMT-BA-e-1414
Vista de página 0
1 2 3 4 5 6 ... 36 37

Resumo do Conteúdo

Página 1 - Bottleweighing Balance

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-

Página 2 - KERN SMT

SMT-BA-e-1414 10

Página 3 - 1 Technical Data

6.2 Select operator and location Select operator: Press the operator button and an option display for admitted operators will appear. Confirm th

Página 4

Select location: Press the Location button and the option displays of the available locations will appear. Confirm the correct location by pressin

Página 5 - 3 Basic Safety Precautions

Press the start button to trigger this screen asking you to select a drink. Drink may be selected via SRCH-CODE SRCH-NAME AUTO-LIST or SCAN funct

Página 6

Enter the name of the drink. In the second information line the information will appear if a selection via selecting fields will be available. Plea

Página 7

Put the selected drink on the balance. Now the contents of the bottle will be displayed as a result in cl. Press the “FRAC/VOL” button and the p

Página 8 - 6 Operation

After pressing the "CLR / BACK" button, the last inventory will be displayed. To delete the last inventory "Clear Registry" wil

Página 9 - 9 SMT-BA-e-1414

Now in the second information line the first listed drink appears. Place the specified bottle. The bottle content will be displayed in „CL“.

Página 10 - SMT-BA-e-1414 10

When the bottle is removed, the following drink appears. Use the „BACK/DRNK“ button to register an other bottle of the previous drink. Use the „

Página 11

Now select the suitable scanner. When the desired scanner is selected, confirm via the return button. Table Scanner Datalogic 19 SMT-BA-e-1414

Página 12

GB KERN SMT Version 1.4 12/2014 Operating instructions Bottleweighing Balance Table of Contents 1 Technical Data ...

Página 13

Handheld Scanner Datalogic Quick Scan Mobile SMT-BA-e-1414 20

Página 14

6.8 Activate automatic storage results: To determine the automatic storage of results from the basic screen, press the „MENU“ button. If the a

Página 15

Now press the „Basic settings“ button. Press the „Store Result:Auto“ button and acknowledge with Enter. 6.9 Input of operator and locations:

Página 16

Now press the „Configuration“ button. Now press the „Operator“ button. To enter a location press the „Location“ button. With the help of the

Página 17

To enter a new operator, overwrite no longer required operators or call up empty description fields by pressing them. Enter the name via the inp

Página 18

Enter the location via the input keyboard field. Save the location via the Enter button. 6.10 Enabling / Disabling the zero passing: Press th

Página 19

Now the selection may take location via the zero-passing button. After that save with the enter button. 6.11 Activation of the automatic switc

Página 20

Now press the „Basic settings“ button. Now press the arrow button Set AUTO INPUT to "ON" and save. 27 SMT-BA-e-1414

Página 21

6.12 Data Transfer PC-SMT, SMT-PC SETUP Setup Balance Bring back balance into the basic screen (STOP/TAKE). Connect the PC to the bala

Página 22

Setup Application Requirements: • Windows XP or higher • Microsoft Office 2003 or higher • .Net Framework 2.0 or higher 1. Go to Settings Menu

Página 23

1 Technical Data KERN SMT 10K-3 Readability (d) 1 g Weighing range (max) 10 000 g Taring range (subtractive) 10 000 g Reproducibility 1 g Line

Página 24

UPLOAD DATA 1. Make sure balance is in basic Mode 2. Choose your File with File → Open SMT-BA-e-1414 30

Página 25

3. Press „Upload from PC > balance“ Button to Upload the chosen File Information: It will upload the same file everytime, till you select ano

Página 26

DOWNLOAD DATA 1. Make sure balance is in basic Mode 2. Press „Download balance PC“ Button 3. You'll be asked for a filename SMT-BA-e-14

Página 27

4. Excel will automatically open containing the transfered Data 33 SMT-BA-e-1414

Página 28

7 Data output RS 232 C Technical data: 8-bit ASCII Code  1 start bit, 8 data bits, 1 stop bit, no parity bit  Baud rate selectable from 2400,

Página 29

8 Service, maintenance, disposal 8.1 Cleaning Before cleaning, please disconnect the appliance from the operating voltage. Please do not use agg

Página 30

9 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process mus

Página 31

10 Declaration of conformity KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax:

Página 32

2 Basic Information (General) It is absolutely necessary that you read and understand the operating instructions prior to installation and commissi

Página 33

3 Basic Safety Precautions 3.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and co

Página 34 - 1

5 Unpacking, Setup and Commissioning 5.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are a

Página 35

5.6 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance

Página 36 - 9 Instant help

6 Operation 6.1 Starting balance by touch screen Welcome display: After touching the touch screen and starting the balance, this screen will app