Kern-sohn DS Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Balanças Kern-sohn DS. KERN & SOHN DS User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating instructions
Precision/ compact balances and
platform scales
KERN 572/573/KB/DS/FKB/KBJ
Version 7.2
10/2014
GB
572/573/KB/DS/FKB/KBJ-BA-e-1472
Vista de página 0
1 2 3 4 5 6 ... 41 42

Resumo do Conteúdo

Página 1 - Operating instructions

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-so

Página 2 - KERN 572/573/KB/DS/FKB/KBJ

2.3 KERN KB/KBJ KERN KB 120-3N KB 240-3N KB 360-3N Readability (d) 0.001 g 0.001 g 0.001 g Weighing range (max) 120 g 240 g 360 g Taring range (sub

Página 3

KERN KB 1200-2N KB 2000-2N KB 2400-2N KB 3600-2N Readability (d) 0.01 g 0.01 g 0.01 g 0.01 g Weighing range (max) 1 200 g 2 000 g 2 400 g 3 600 g Tar

Página 4 - 1 MODE - MENUE

KERN KB 10000-1N KB 10k0.05N Readability (d) 0.1 g 0.05 g Weighing range (max) 10 000 g 10 000 g Taring range (subtractive) 10 000 g 10 000 g Re

Página 5

KERN KB 650-2NM KB 6500-1NM KBJ 650-2NM Accuracy class II II II Readability (d) 0.01 g 0.1 g 0.01 g Verification value (e) 0.1 g 1 g 0.1 g Weighing r

Página 6 - 2 Technical data

2.4 KERN DS KERN DS 3K0.01S DS 5K0.05S DS 8K0.05 DS 10K0.1S Readability (d) 0.01 g 0.05 g 0.05 g 0,1 g Weighing range (max) 3 000 g 5 000 g 8 000 g

Página 7

KERN DS 16K0.1 DS 20K0.1 DS 30K0.1 Readability (d) 0.1 g 0.1 g 0.1 g Weighing range (max) 16 000 g 20 000 g 30 000 g Taring range (subtractive) 16 0

Página 8

KERN DS 36K0.2 DS 30K0.1L DS 36K0.2L DS 60K0,2 Readability (d) 0.2 g 0.1 g 0.2 g 0.2 g Weighing range (max) 36 000 g 30 000 g 36 000 g 60 000 g Tarin

Página 9

KERN DS 65K0.5 DS 100K0.5 DS 150K1 Readability (d) 0.5 g 0.5 g 1 g Weighing range (max) 65 000 g 100 000 g 150 000 g Taring range (subtractive) 65 0

Página 10

KERN DS 65K1M Accuracy class II Readability (d) 1 g Verification value (e) 10 g Weighing range (max) 65 000 g Minimum load (Min) 50 g Taring range (s

Página 11

2.5 KERN FKB KERN FKB 6K0.02 FKB 8K0.05 FKB 16K0.05 FKB 16K0.1 Readability (d) 0.02 g 0.05 g 0.05 g 0.1 g Weighing range (max) 6 000 g 8 000 g 16

Página 12

GB KERN 572/573/KB/DS/FKB/KBJ Version 7.2 10/2014 Operating instruction Precision/compact balances and platform scales Table of contents: 1 MODE

Página 13

KERN FKB 36K0.1 FKB 36K0.2 FKB 65K0.2 FKB 65K0.5 Readability (d) 0.1 g 0.2 g 0.2 g 0.5 g Weighing range (max) 36 000 g 36 000 g 65 000 g 65 000 g Tar

Página 14

KERN FKB 8K0.1M FKB 65K1M Accuracy class II II Readability (d) 0.1 g 1 g Verification value (e) 1.0 g 10 g Weighing range (max) 8 000 g 65 000 g Min

Página 15

3 Fundamental information (general) It is essential to read through and observe the complete operating instructions before in-stalling and commissio

Página 16

4 Fundamental safety information 4.1 Observe the information in the operating instructions Carefully read this operation manual before setup and c

Página 17

6 Unpacking, installation and commissioning 6.1 Place of installation, place of use The balance is constructed in such a way that reliable weighing

Página 18

6.4 Battery operation FKB  To insert the batteries (6 x 1.5 V) remove the battery compartment cover. Remove it with the help of a coin.

Página 19

6.8 Adjusting (go to 7.2.6) Using a precision weight, the accuracy of the balance can be checked at any time and adjusted. Warning: With verified b

Página 20

6.8.2 Adjustment of the balance KBJ with internal adjustment weight After expiring of the warm-up time (wait > 299s), the balance KBJ is autom

Página 21

7 Operation 7.1 Display control panel Keyboard ON / OFF Print weighing result in MODE: No / descending in % and counting mode: Form ref

Página 22

7.2 Operation 7.2.1 Weighing with Tare 7.2.2 Count – Selection reference piece 7.2.3 Percent % 7.2.4 Formula Weighing 7.2.5 Tolerance Weig

Página 23 - 5 Transport and storage

7 Operation ... 28 7.1 Display control

Página 24

572/573/KB/DS/FKB/KBJ-BA-e-1472 30

Página 25

7.2.6 Adjust 7.2.7 Preselect Tare 7.2.8 Auto Tare active 7.2.9 Filter / Speed 7.2.10 Auto Off active 7.2.11 Variable Factor 7.2.12 Preselect Unit

Página 26

572/573/KB/DS/FKB/KBJ-BA-e-1472 32

Página 27

7.2.13 Animal weighing:  Activate via mode/animal weigh. Y/N (4xMode)  Put container without measured object on the weighing surface and tare 

Página 28 - 7 Operation

7.2.15 Contents of the form printout: MODE / PRINTER / PRINTERFORM Var 1 Type xx = Gross MODE Var 1 Row xx XXxx MODE Var 1 Type 02 = Gross Var 1

Página 29

7.3 Display background illumination After having switched on your balance and the zero display, press the „MODE“ button to select the menu point „Ba

Página 30

7.5 RS 232 C Data output via interface RS 232 C RS 232 C Data output via interface RS 232 C General information As a condition for the data transfer

Página 31

7.5.1 Description of the data transfer Structure of each data transfer: Bit-Nr. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B* N N N B B B B B 0

Página 32

7.7 Underfloor weighing Objects which, because of their size or shape, cannot be put on the scale, can be weighed by means of underfloor weighing.

Página 33

8 Maintenance, upkeep, disposal 8.1 Cleaning Please disconnect the device from the operating voltage before cleaning. Only use a cloth dampened w

Página 34 - Printerform

1 MODE - MENUE Models 572 / KB / DS / FKB / non-verifiable: Important! The modified settings - as well as the adjustment - must be stored when s

Página 35

9 Troubleshooting The balance should be switched off for a short time following an interruption in the pro-gramme sequence and disconnected from th

Página 36

10 Declaration of conformity KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax:

Página 37

KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet

Página 38 - ! NOTE !

Models 573-NM; KB-NM; DS-M; FKB-M; KBJ-NM: Important! The modified settings - as well as the adjustment - must be stored when switching-off, via

Página 39

2 Technical data 2.1 KERN 572 KERN 572-30 572-31 572-32 572-33 Readability (d) 0.001 g 0.001 g 0.001 g 0.01 g Weighing range (max) 240 g 300 g 420

Página 40 - 9 Troubleshooting

KERN 572-35 572-37 572-39 572-43 Readability (d) 0.01 g 0.01 g 0.01 g 0.1 g Weighing range (max) 2400 g 3000 g 4200 g 10000 g Taring range (subtracti

Página 41 - Signature

KERN 572-45 572-49 572-55 572-57 Readability (d) 0.05 g 0.1 g 0.05 g 0.1 g Weighing range (max) 12000 g 16000 g 20000 g 24000 g Taring range (subtrac

Página 42

2.2 KERN 573 KERN 573-34NM 573-46NM Accuracy class II II Readability (d) 0.01 g 0.1 g Verification value (e) 0.1 g 1 g Weighing range (max) 650 g 65

Comentários a estes Manuais